欢迎进入济南济柴环能燃气发电设备·必发官网!

公司·必发·新闻

燃气发电机组排温过高的三个处理办法

返回 2024.04.08 来源:http://www.xifiao.com 0

用户在使用燃气发电机组的过程中可能会遇到排温突然过高的问题,可根据下面三个办法处理。

Users may encounter the problem of sudden high exhaust temperature during the use of gas generator sets. The following three methods can be used to deal with it.

必发

1. 查看机组运行时各缸的燃气调节阀是否松动,若无松动,还需停机检查点火线圈 与火花塞是否有故障。

1. Check if the gas regulating valves of each cylinder are loose during the operation of the unit. If they are not loose, stop the machine and check if there are any faults in the ignition coil and spark plug.

2. 如果单缸排温异常,需要检查一下是不是仪表显示的问题。

If the exhaust temperature of a single cylinder is abnormal, it is necessary to check if there is a problem with the instrument display.

3. 如果整体排温异常,需要检查是否是气体浓度变化或点火不良导致。

If the overall exhaust temperature is abnormal, it is necessary to check whether it is caused by changes in gas concentration or poor ignition.

厂家介绍,当无法确切排查到故障根源时,可以考虑置换法。例如,如果考虑是点火控制器的故障,那么检查时可以单独对点火控制器进行调整,观察故障是否还会发生,来确定是否是点火控制器的问题。

The manufacturer suggests that when the root cause of the malfunction cannot be accurately identified, the replacement method can be considered. For example, if the fault is considered to be with the ignition controller, it can be adjusted separately during inspection to observe whether the fault will still occur and determine whether it is a problem with the ignition controller.

·必发·新闻搜索
济南济柴环能燃气发电设备·必发
  • 服务热线

    0531-62325028
    0531-69951266

燃气发电机组排温过高的三个处理办法

用户在使用燃气发电机组的过程中可能会遇到排温突然过高的问题,可根据下面三个办法处理。

Users may encounter the problem of sudden high exhaust temperature during the use of gas generator sets. The following three methods can be used to deal with it.

20220308032702243.png

1. 查看机组运行时各缸的燃气调节阀是否松动,若无松动,还需停机检查点火线圈 与火花塞是否有故障。

1. Check if the gas regulating valves of each cylinder are loose during the operation of the unit. If they are not loose, stop the machine and check if there are any faults in the ignition coil and spark plug.

2. 如果单缸排温异常,需要检查一下是不是仪表显示的问题。

If the exhaust temperature of a single cylinder is abnormal, it is necessary to check if there is a problem with the instrument display.

3. 如果整体排温异常,需要检查是否是气体浓度变化或点火不良导致。

If the overall exhaust temperature is abnormal, it is necessary to check whether it is caused by changes in gas concentration or poor ignition.

厂家介绍,当无法确切排查到故障根源时,可以考虑置换法。例如,如果考虑是点火控制器的故障,那么检查时可以单独对点火控制器进行调整,观察故障是否还会发生,来确定是否是点火控制器的问题。

The manufacturer suggests that when the root cause of the malfunction cannot be accurately identified, the replacement method can be considered. For example, if the fault is considered to be with the ignition controller, it can be adjusted separately during inspection to observe whether the fault will still occur and determine whether it is a problem with the ignition controller.

下一篇:
2024-10-04